When installation is complete, secure enclosure door with screws provided or keylock refer to 900fa instructions for additional info refer to appropriate instructions if any board shown below is factoryinstalled. Data sheet 850010247 intelligent 3d multisensor detector. Sigc270f, sigc270b, siga 270p, sigc270pb, siga 278. They include the siga ts4 trim skirt which is used to cover the mounting ears on the base. Siga 270 models feature our familiar teardrop design with simple positive pull action and sturdy diecast metal body one stage ga, two stage presignal, and double action models siga 270 models are available for one or two stage alarm systems. The sigacc1s mounts to a standard north american twogang electrical box, making it ideal for locations where only one module is required. Jul 02, 2011 introducing the worlds most powerful multisensor analogue sensing and digitally communicating devices in the life safety industry. Sac bus wire lengths versus number of doors and current loads using 16. Installation ps902 power supply instructions 44487023. Verify that all field wiring is free of opens, shorts, and ground faults. Zb164 class b zone card installation sheet pn 3100188 zr8 relay card installation sheet pn 3100190 sigaaps auxiliary power supply installation sheet pn 387342 signature series intelligent smoke and heat detectors applications bulletin pn 270145 signature series component installation manual pn 270497. Signature series component installation manual relay electrical. The sigadh housing with sigaps smoke detector and a. Fci 7200 est edwards irc3 ge edwards est notifier system 7200 fire alarm fire alarm strobe red simplex fire panel simplex grinnell fci 7200 fire alarm est siga autocall grinnell thorn simplex fire alarm horn autocall tfx simplex fire alarm control fire alarm signal strobe autocall grinnell simplex horn simplex 4100 fire alarm wall mount strobe honeywell firelite simplex pull addressable pull.
Philips hue lightstrip plus owners manual page 1 of 17. The siga cc1 and siga cc2 mount to standard north american 2gang electrical boxes, making them ideal for locations where only one module is required. The sigaled must not exceed remote led is supported by the 10 ohms standard base. The detector analyzes the sensor data to determine whether to initiate an alarm.
Some features described here may not be supported by all control systems. Added section 6 to chapter 5 of the manual to provide guidelines for the installation and operation. Ada compliant compatible with most brands of pull stations fast installation screw terminal wire connection onegang mounting the manual. Available in a two wire version or a four wire version with separate controllers able to serve two detectors, installers have the freedom to configure the superduct to suit the tight spaces typical. Ps engineering incorporated pm faa tso approved intercom installation and operation manual 200 190 0002 5 rev. Summary of contents of owners manual for philips hue lightstrip plus. Est3 compatibility list 3aadc1 addressable analog device controller compatible devices 1 agency models ul 1251f 1551fb 2251f 2251tf 2551fb 2551tb 5251f 5251f 5551fb.
Smoke detector gathers analog information from its smoke sensing automatic device mapping the loop controller learns where element and converts it into digital signals. The sigaled alarm indicator is suitable for use with the sigasb detector base only. The signature series sigapd optical smoke detector brings. Global leader in fire alarm, mass notification and hazard warning. Before replacing a sigacc1 module, tag the wires to ensure correct reconnection. Sigasd edwards est intelligent superduct detector life safety consultants is here to ensure your fire and smoke detectors are always in working order.
Twenty prealarm sensitivity values, set in 5% increments. A maximum of one can be operated for each detector. The edwards est sigaps is compatible for use only with ests signature loop controller. Separate io and data loop connections are made to each module. System smoke detectors 2 foreword the use of early warning fire and smoke detection systems results in significant reduction in fire deaths. The last time to order the detector siga2 ps almost made in us.
Whether edwards detection and alarm solutions are protecting the lives and livelihoods of the people who make businesses run, or who receive treatment at healthcare institutions. Jun 08, 2017 using the features of the siga hdt and navigating the menus. Signature series component installation manual pn 270497 revised. Page 14 4 page 15 distributor lightstri ps cw i0275 w. Features20 to 158 f 29 to 70 c operating range with 100 ftmin. Edwards est sigaps intelligent photoelectric smoke detector. Sounder bases siga ab4g, siga ab4glf, siga ab4gt, siga tcdr 73001657. Download manual download est international siga ps manual est international siga ps. The contents of the traffic signals manual have changed as follows. But recently the siga2 ps now replace with siga pd, i think its may be ok.
Siga todas las advertencias, precauciones e instrucciones. Philips hue lightstrip plus owners manual manuals brain. Edwards est sigaps photoelectric smoke detector life. With the edwards est smoke detector siga ps, an intelligent photoelectric smoke detector, you will have access to the features and power needed to ensure you will always be alerted at the first signs of a fire. Siga sb detector base installation sheet free download as pdf file. Mount the sigasb on a compatible electrical box using the screws provided with the electrical box. Original instruction manual printed on chlorinefree paper printing inks contain vegetabl. Edwards est sigahrd fixedror heat detector replaces siga. Simplex 20989201 photoelectric smoke detector life. Upon command from the loop controller, the sigacr relay energizes. The detector may be installed in rooms with ambient temperatures up to 120 o f 49 o c. Data sheet 850010640 sounder bases for intelligent detectors. Page 1 of 10 data sheet 850050 not to be used for installation purposes.
Available in a two wire version or a four wire version with separate controllers able to serve two detectors, installers have the freedom to configure the superduct to suit the tight spaces typical of duct applications and still have ready access to field connections. Edwards est siga2ps intelligent photoelectric smoke detector. The superduct sd series duct detectors offers the convenience of modular design plus the power of advanced sensing technology. Sigacc1 single input signal module installation sheet.
In order for the dialer to be able to seize the phone line to report an alarm or. Siga crmcr control relay modules general the siga crmcr control relay module is an intelligent addressable device with a form c dry relay contact to control appliances such as door closers, fans, and dampers. The siga mcc1 and siga mcc2 are part of the uio family of plugin signature series modules. The siga sb4, siga rb4, and siga ib4 mount to north american four inch square electrical boxes in addition to the above boxes. The sigaiphs intelligent 4d multisensor detector gathers analog information from. Remote booster power supply technical reference manual 3 getting started description the 6. Buy edwards sigaled fire alarm indicator remote led. Sigaim isolator module installation sheet pn p0475501788en rev 09 iss 22jun15. The primary difference between both systems is the type of sprinkler head or nozzle that terminates the pipes.
Check your control panels installation and operation guide for details. Edwards est sigapd intelligent smoke detector rybb fire. Intelligent photoelectric smoke detector edwards free bim. The result is a compact unit with an attractive appearance. Edwards fire alarm systems, life safety systems, industrial. Siga2 ps intelligent photoelectric smoke detector installation sheet. Est3 compatibility list engineering systems technology. The single stage double action siga 278 features a rugged lexan housing with keyed reset mechanism. Write the address assigned to the detector on the label provided and apply the label to the inside rim of the base.
When installation is complete, secure enclosure door with screws provided or keylock refer to 900fa instructions for additional info. Pm 2 place intercom system operation and installation manual. Installation in accordance with this manual, applicable codes, and the instructions of the authority having jurisdiction is mandatory. The sigacr is an addressable device used to provide one form c dry relay contact to control external appliances door closers, fans, dampers, etc. While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, utcfs assumes no responsibility for errors or omissions. The signature series model siga2ps intelligent photoelectric smoke detector is an intelligent device that uses an optical sensing chamber to detect smoke. The signature series model sigaps intelligent photoelectric. Siga ps signature photoelectric smoke detector siga2 ps signature photoelectric smoke detector siga sd signature superduct photoelectric duct smoke detector siga hfs signature fixed temperature heat detector siga2hfs signature fixed temperature heat detector siga hrs signature combination fixed temperature and rateofrise. Use this installation sheet in conjunction with the installation manual of the dsc equipment the pcl422 is. This is a reconditioned, photoelectric smoke detector that is compatible with several simplex parts and accessories. Siga sd edwards est intelligent superduct detector life safety consultants is here to ensure your fire and smoke detectors are always in working order.
Siga sb detector mounting base standard siga sb4 4inch detector mounting base w siga ts4 trim skirt siga rb detector mounting base wrelay siga rb4 4inch. Data sheet 850010640 sounder bases for intelligent. For additional information, contact the life safety consultants team at 888 5570558, or email us at. Signature series component installation manual free download as pdf file. Sigacr control relay module free fire alarm manuals.
Page 3 of 4 specifications compatible smoke detectors sigaps sigaphs sigaiphs smoke sensing elements photoelectric light scattering principle photoelectric light scattering principle heat 5. Ab4, crr, mab, mcr, mcrr, mcc1, mcc2, mct2, uio2, and uio6r. Est3 installation and service manual i content important information v ul 864 9th edition requirements vii about this manual x the est3 library xii related documentation xiii chapter 1 system overview 1. Installation compatibility conditions are expected. Thats why we offer a wide range of replacement parts and components like the edwards est intelligent superduct detector siga sd. This document provides guidance for the proper operation of fire detection systems for those who apply.
Introducing the worlds most powerful multisensor analogue sensing and digitally communicating devices in the life safety industry. Instructions this page is the print specification for the publication. Stihl bg 55, 65, 85, sh 55, 85 owners instruction manual. When the loop controller sends a command, the module relay activates the normally open and normally closed contact.
Designed for easy installation and superb reliability, superduct represents the perfect balance of practical design and advanced technology. Rated 32f to 120f 0c to 49c when used with model sigaps or sigais. The system firmware ensures that the relay is in the proper onoff state. It features a red led on a onegang plastic plate and can be installed remote or directly on the sigadh duct housing. Standard detector base, sigasb, sigasb4 this is the basic mounting remote led base for edwards signature max resistance per wire series detectors. C fixed temperature ionization unipolar photoelectric light scattering principle heat. Manual reset temporarily close to reset fire alarm contact closed no fire open fire note. Page 2 of 4 d ata s h e e t s850010585 not to be used for installation purposes. Signature series component installation manual p n 270497 revision status revision date reason for change. Data sheet e850010646 intelligent smoke detector nidux. Issue 5 application the superduct twowire duct smoke detector is ideally suited to applications where early indication of combustion is required within.
Standard base siga sb, siga sb4 this is the basic mounting base. A 2 place jack kit is available, part number 250 000 0040. Siga sb detector base installation sheet electrical wiring wire. The signature optica series siga osd smoke detector brings advanced optical sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Ambient temperature has very little affect on the detector. Please refer to est3 installation and service manual for complete system. Siga sb detector base installation sheet description the siga sb is the standard base for signature series detectors. Intelligent 4d multisensor detector steel fire equipment. Data sheet 850010543 issue 3 not to be used for installation purposes. Standard base sigasb, sigasb4 this is the basic mounting base.
Multisensor smoke detector sigaps photoelectric smoke detector sigarb. The sooner a fire is detected, the better the out come for saving lives. But now i think its so bad when the siga detector serial change from made in us to china. Edwards est siga2 ps intelligent photoelectric smoke detectors are only for use with signature loop controller. The sigaps detectors sensitivity remains stable in wind the sigaps detectors are compatible only with ests signature velocities up to 5,000 ftmin 25. See signature loop controller catalog sheet for detailed wiring requirement specifications. The sigasb is the standard base for signature series detectors. Edwards signaling sd series superduct tm duct smoke. It connects the detector to the signaling line circuit slc, and provides wiring terminals for connection to a siga led. The detector analyzes the sensor data to determine whether to initiate an alarm the signature series model siga2 ps intelligent photoelectric smoke detector is an intelligent device that uses an optical sensing chamber to detect smoke. At life safety consultants, we have a wide variety of excellent products to choose from. Relay detector base, siga rb, siga rb4 test fire type of detector siga is ion siga ps photo siga hrs and siga hfs rateofrisefixed temp. Page 1 in the unlikely event that an unwanted alarm does take place, the control panels history file can be called up to help isolate the ests signature series model sigaps intelligent photoelectric problem and prevent it from happening again. The sigaps detector s sensitivity remains stable in wind velocities up to 5,000 ftmin 25.
Photoelectric detectors have a wide range of sensing capabilities but are best suited for detecting slow, smoldering fires. You can activate the bps from options modules or from a control circuit. Ests sigaps intelligent photoelectric smoke detectors are compatible only with ests signature loop controller. Edwards siga led fire alarm indicator remote led product information package dimensions 4. A smoke detectors sensitivity is a measurement of the threshold in which the unit will alarm upon detecting smoke. The signature series model siga2 ps intelligent photoelectric smoke detector is an intelligent device that uses an optical sensing chamber to detect smoke. It is not part of the artwork for the publication and must be removed before production.
92 1629 110 919 80 191 352 624 159 1019 225 136 1152 120 499 178 1401 663 1254 1613 1102 5 28 1511 191 1100 1232 618 723 1189 1217 40 1224 1101 1027 117 1058